top of page

TAJ 1 Commercial Building

We performed a detailed CFD analysis and simulation study for the Taj 1 Commercial Building in Oman, assessing airflow dynamics, temperature distribution, and ventilation efficiency to optimise HVAC performance, thermal comfort, and overall indoor environmental quality.

taj .jpg

    THE CHALLENGE

The Taj 1 Commercial Spaces was destined for commercial use with offices, retails spaces as well as underground parking, a mini market, bank and other facilities. It was therefore paramount that a well-researched and effective fire protection system design, combined with technology to optimise thermal comfort for shoppers and occupants was developed. ​

SERVICES PROVIDED

 

CFD Analysis 

​

CFD Simulation

OUR APPROACH

To ensure a safe, energy-efficient, and comfortable indoor environment for the Taj 1 Commercial Building in Oman, we employed Computational Fluid Dynamics (CFD) as a key tool in the design and optimisation process. Our analysis addressed a wide range of conditions, with particular focus on smoke and fire scenarios, given their potential to escalate rapidly and pose serious risks to both occupants and property.

We developed detailed simulations to account for airflow patterns, temperature distribution, and contaminant transport, providing a comprehensive understanding of the building’s thermal and ventilation performance. Additional environmental factors, such as occupancy profiles, internal heat gains, and local weather conditions, were incorporated to ensure that the analysis reflected real-world operating conditions.

By aligning our methodology with ASHRAE standards, we were able to optimize the HVAC systems and overall building design for energy efficiency and occupant comfort. The CFD simulations highlighted critical areas for improvement in airflow and temperature uniformity, while also validating the building’s resilience under fire and smoke scenarios.

This comprehensive approach enabled data-driven design decisions, enhancing occupant safety, well-being, and overall indoor environmental quality. The project demonstrates how advanced CFD modeling can support high-performance, resilient, and sustainable building design in complex commercial environments.

OUTCOME

​​

1 Countries, 1 Time Zone

1 CFD Analysis & Simulation Report 

 

Our collaboration on the Taj 1 Commercial Building played a critical role in enhancing fire prevention and protection strategies. By leveraging advanced CFD analysis and simulation tools, we were able to model smoke and fire behavior, optimise evacuation scenarios, and assess the performance of fire safety systems with high precision.

​

In parallel, the simulations provided valuable insights into thermal comfort and airflow distribution, ensuring that both permanent occupants and temporary visitors experience optimal indoor environmental conditions. This integrated approach allowed us to maximise safety, comfort, and energy efficiency, supporting data-driven design decisions and enhancing overall building performance.